Reworked IkeaOutlet into more generic outlet that also (optionally) supports power measurement
This new power measurement feature is used to turn the kettle off automatically once it is done boiling
This commit is contained in:
36
config.lua
36
config.lua
@@ -78,14 +78,14 @@ automation.device_manager:add(WakeOnLAN.new({
|
||||
}))
|
||||
|
||||
-- TODO: Update this to 10.0.0.101 when DHCP want to finally work
|
||||
local living_mixer = IkeaOutlet.new({
|
||||
local living_mixer = OutletOnOff.new({
|
||||
name = "Mixer",
|
||||
room = "Living Room",
|
||||
topic = mqtt_z2m("living/mixer"),
|
||||
client = mqtt_client,
|
||||
})
|
||||
automation.device_manager:add(living_mixer)
|
||||
local living_speakers = IkeaOutlet.new({
|
||||
local living_speakers = OutletOnOff.new({
|
||||
name = "Speakers",
|
||||
room = "Living Room",
|
||||
topic = mqtt_z2m("living/speakers"),
|
||||
@@ -118,12 +118,12 @@ automation.device_manager:add(IkeaRemote.new({
|
||||
end,
|
||||
}))
|
||||
|
||||
local function off_timeout(duration)
|
||||
local function kettle_timeout()
|
||||
local timeout = Timeout.new()
|
||||
|
||||
return function(self, on)
|
||||
if on then
|
||||
timeout:start(duration, function()
|
||||
return function(self, state)
|
||||
if state.state and state.power < 100 then
|
||||
timeout:start(3, function()
|
||||
self:set_on(false)
|
||||
end)
|
||||
else
|
||||
@@ -132,13 +132,13 @@ local function off_timeout(duration)
|
||||
end
|
||||
end
|
||||
|
||||
local kettle = IkeaOutlet.new({
|
||||
local kettle = OutletPower.new({
|
||||
outlet_type = "Kettle",
|
||||
name = "Kettle",
|
||||
room = "Kitchen",
|
||||
topic = mqtt_z2m("kitchen/kettle"),
|
||||
client = mqtt_client,
|
||||
callback = off_timeout(debug and 5 or 300),
|
||||
callback = kettle_timeout(),
|
||||
})
|
||||
automation.device_manager:add(kettle)
|
||||
|
||||
@@ -164,6 +164,20 @@ automation.device_manager:add(IkeaRemote.new({
|
||||
callback = set_kettle,
|
||||
}))
|
||||
|
||||
local function off_timeout(duration)
|
||||
local timeout = Timeout.new()
|
||||
|
||||
return function(self, state)
|
||||
if state.state then
|
||||
timeout:start(duration, function()
|
||||
self:set_on(false)
|
||||
end)
|
||||
else
|
||||
timeout:cancel()
|
||||
end
|
||||
end
|
||||
end
|
||||
|
||||
automation.device_manager:add(LightOnOff.new({
|
||||
name = "Light",
|
||||
room = "Bathroom",
|
||||
@@ -180,8 +194,8 @@ automation.device_manager:add(Washer.new({
|
||||
event_channel = automation.device_manager:event_channel(),
|
||||
}))
|
||||
|
||||
automation.device_manager:add(IkeaOutlet.new({
|
||||
outlet_type = "Charger",
|
||||
automation.device_manager:add(OutletOnOff.new({
|
||||
presence_auto_off = false,
|
||||
name = "Charger",
|
||||
room = "Workbench",
|
||||
topic = mqtt_z2m("workbench/charger"),
|
||||
@@ -189,7 +203,7 @@ automation.device_manager:add(IkeaOutlet.new({
|
||||
callback = off_timeout(debug and 5 or 20 * 3600),
|
||||
}))
|
||||
|
||||
automation.device_manager:add(IkeaOutlet.new({
|
||||
automation.device_manager:add(OutletOnOff.new({
|
||||
name = "Outlet",
|
||||
room = "Workbench",
|
||||
topic = mqtt_z2m("workbench/outlet"),
|
||||
|
||||
Reference in New Issue